2019 journal article

Relationship between Human Perception of Softness and Instrument Measurements

BIORESOURCES, 14(1), 780–795.

By: Y. Wang n, T. De Assis n, F. Zambrano n, L. Pal n, R. Venditti n, S. Dasmohapatra*, J. Pawlak n, R. Gonzalez n

co-author countries: United States of America 🇺🇸
author keywords: Formation; Tissue softness analyzer; Softness; Bath tissue; TS7; Panel test
Source: Web Of Science
Added: March 11, 2019

Softness, as a subjective perception, is difficult to define and quantify. For decades, panel tests have been used to judge differences in the softness of hygiene tissue samples. Panel tests can be a time-consuming and expensive process. A number of protocols have been developed to quantify the physical properties of tissues associated with softness. The Tissue Softness Analyzer (TSA) by Emtec has gained popularity in characterizing the physical properties of tissues associated with softness. The instrument was designed with softness in mind and attempts to simulate the touch of the human hand. There is currently no comprehensive study that compares the results from a TSA and human panel. In this work, panel tests were used to validate the performance of the TSA with bath tissue. It was determined that one component of the TSA measurements (TS7) linearly correlated with the panel results. Among all of the algorithms available for use with the TSA, the TP2 algorithm most accurately predicted the panel scores. The TSA performed better in predicting the softness of the samples that were dried with a conventional wet press or creped-through air-dryer.