2022 journal article

Computed Tomography Assessment of Tidal Lung Overinflation in Domestic Cats Undergoing Pressure-Controlled Mechanical Ventilation During General Anesthesia

FRONTIERS IN VETERINARY SCIENCE, 9.

author keywords: computed tomography; pulmonary overinflation; ventilator-induced lung injury; tidal volume; controlled ventilation; cats
TL;DR: Ventilation with 5 and 7 cmH2O of airway pressure prevents overinflation in healthy cats with highly compliant chest walls, despite presenting acidemia by respiratory acidosis. (via Semantic Scholar)
Source: Web Of Science
Added: May 10, 2022

ObjectiveThis study aimed to evaluate lung overinflation at different airway inspiratory pressure levels using computed tomography in cats undergoing general anesthesia.Study DesignProspective laboratory study.AnimalsA group of 17 healthy male cats, aged 1.9–4.5 years and weighing 3.5 ± 0.5 kg.MethodsSeventeen adult male cats were ventilated in pressure-controlled mode with airway pressure stepwise increased from 5 to 15 cmH2O in 2 cmH2O steps every 5 min and then stepwise decreased. The respiratory rate was set at 15 movements per min and end-expiratory pressure at zero (ZEEP). After 5 min in each inspiratory pressure step, a 4 s inspiratory pause was performed to obtain a thoracic juxta-diaphragmatic single slice helical CT image and to collect respiratory mechanics data and an arterial blood sample. Lung parenchyma aeration was defined as overinflated, normally-aerated, poorly-aerated, and non-aerated according to the CT attenuation number (−1,000 to −900 HU, −900 to −500 HU, −500 to −100 HU, and −100 to +100 HU, respectively).ResultAt 5 cmH2O airway pressure, tidal volume was 6.7± 2.2 ml kg−1, 2.1% (0.3–6.3%) of the pulmonary parenchyma was overinflated and 84.9% (77.6%−87.6%) was normally inflated. Increases in airway pressure were associated with progressive distention of the lung parenchyma. At 15 cmH2O airway pressure, tidal volume increased to 31.5± 9.9 ml kg−1(p< 0.001), overinflated pulmonary parenchyma increased to 28.4% (21.2–30.6%) (p< 0.001), while normally inflated parenchyma decreased 57.9% (53.4–62.8%) (p< 0.001). Tidal volume and overinflated lung fraction returned to baseline when airway pressure was decreased. A progressive decrease was observed in arterial carbon dioxide partial pressure (PaCO2) and end-tidal carbon dioxide (ETCO2) when the airway pressures were increased above 9 cmH2O (p< 0.001). The increase in airway pressure promoted an elevation in pH (p< 0.001).Conclusions and Clinical RelevanceVentilation with 5 and 7 cmH2O of airway pressure prevents overinflation in healthy cats with highly compliant chest walls, despite presenting acidemia by respiratory acidosis. This fact can be controlled by increasing or decreasing respiratory rate and inspiratory time.