Works (9)

Updated: October 14th, 2024 09:57

2024 journal article

Design, Fabrication, and Characterization of Capacitive Micromachined Ultrasonic Transducers for Transcranial, Multifocus Neurostimulation

Micromachines, 15(9), 1106.

By: T. Ibn Minhaj n, M. Annayev n, O. Adelegan n, A. Biliroğlu n, F. Yamaner n & Ö. Oralkan n

author keywords: neurostimulation; capacitive micromachined ultrasonic transducer (CMUT); single-element; large area transducer; fabrication; design; FEM; non-invasive; ultrasound; nonhuman primate model
Sources: Web Of Science, ORCID, Crossref, NC State University Libraries
Added: September 1, 2024

2024 article

Fabrication of 32 x 32 2D CMUT Arrays on a Borosilicate Glass Substrate With Silicon-Through-Wafer Interconnects Using Non-Aligned and Aligned Anodic Bonding

Annayev, M., Biliroglu, A. O., Sennik, E., Yamaner, F. Y., & Oralkan, O. (2024, August 22). JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, Vol. 8.

By: M. Annayev n, A. Biliroglu n, E. Sennik n, F. Yamaner n & O. Oralkan n

author keywords: Capacitive micromachined ultrasonic transducer (CMUT); 2D arrays; glass substrate; silicon-through-glass vias (Si-TGV); anodic bonding; Capacitive micromachined ultrasonic transducer (CMUT); 2D arrays; glass substrate; silicon-through-glass vias (Si-TGV); anodic bonding
Sources: Web Of Science, ORCID, NC State University Libraries
Added: September 1, 2024

2023 journal article

Design and Fabrication of 1-D CMUT Arrays for Dual-Mode Dual-Frequency Acoustic Angiography Applications

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 71(1), 191–201.

author keywords: Acoustic angiography (AA); capacitive micromachined ultrasonic transducer (CMUT); dual-mode dual-frequency array; glass substrate
TL;DR: A novel scheme with a capacitive micromachined ultrasonic transducer array to receive high-frequency microbubble harmonics in collapse mode and to transmit a low-frequency high-pressure pulse by releasing the CMUT plate from collapse and pull it back to collapse again in the same transmit-receive cycle. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Sources: Web Of Science, ORCID, NC State University Libraries
Added: December 13, 2023

2022 article

A pre-charged CMUT structure with a built-in charge storage capacitor

2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS).

By: M. Annayev n, F. Yamaner n & O. Oralkan n

author keywords: Pre-charged; zero-bias; energy transfer; capacitive micromachined ultrasonic transducer; CMUT
UN Sustainable Development Goal Categories
7. Affordable and Clean Energy (OpenAlex)
Sources: Web Of Science, NC State University Libraries
Added: February 6, 2023

2022 journal article

An Ultrasonic Energy Harvesting IC Providing Adjustable Bias Voltage for Pre-Charged CMUT

IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 16(5), 842–851.

By: L. Zhao*, M. Annayev n, O. Oralkan n & Y. Jia*

author keywords: Acoustics; Video recording; Integrated circuits; Energy harvesting; Clocks; Voltage control; Distributed Bragg reflectors; High voltage charge pump; pre-charged CMUT; ultrasonic energy harvesting; wireless power transmission
MeSH headings : Ultrasonics; Ultrasonography; Equipment Design; Transducers; Electric Capacitance
UN Sustainable Development Goal Categories
7. Affordable and Clean Energy (OpenAlex)
Sources: Web Of Science, ORCID, NC State University Libraries
Added: December 1, 2022

2022 article

Performance Assessment of Ultra-Wideband and Dual-Mode 1D CMUT Arrays for Acoustic Angiography

2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS).

By: E. Belekov n, K. Bautista*, M. Annayev n, O. Adelegan n, A. Biliroglu n, T. Kierski*, J. Sanders n, R. Kemal n ...

author keywords: capacitive micromachined ultrasonic transducer; ultra-wideband; dual-mode; acoustic angiography; ultrasound handheld probe; contrast agent
TL;DR: A custom 256-channel imaging probe with integrated low-noise amplifiers and supporting power circuitry is designed with a strong use case for the UWB and dual-mode CMUT arrays in acoustic angiography applications. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Sources: Web Of Science, NC State University Libraries
Added: February 6, 2023

2021 article

Design and Fabrication of 1D CMUT Arrays for Dual-Mode Acoustic Angiography Applications - Preliminary Results

INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021).

By: M. Annayev n, O. Adelegan n, F. Yamaner n, P. Dayton n & O. Oralkan n

author keywords: Dual-mode dual-frequency; capacitive micromachined ultrasonic transducer; CMUT; acoustic angiography
TL;DR: Finite element model simulation results show that the fabricated devices can transmit at low frequency and receive echoes at high frequency (> 15 MHz), which are verified by experimental results. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Sources: Web Of Science, NC State University Libraries
Added: August 15, 2022

2021 article proceedings

Design and Fabrication of Single-Element CMUTs for Forming a Transcranial Array for Focused Beam Applications

Event: 2021 IEEE International Ultrasonics Symposium (IUS)

author keywords: ultrasound; focused; ultrasound; transducer; transcranial; fabrication; stimulation
UN Sustainable Development Goal Categories
Sources: Web Of Science, NC State University Libraries, ORCID, Crossref
Added: August 15, 2022

2021 article

Design of Pre-Charged CMUTs with a Metal Floating Gate

INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021).

By: M. Annayev n, O. Adelegan n, F. Yamaner n & O. Oralkan n

author keywords: Pre-charged; zero-bias; energy harvesting; capacitive micromachined ultrasonic transducer; CMUT
UN Sustainable Development Goal Categories
Sources: Web Of Science, NC State University Libraries
Added: August 15, 2022

Citation Index includes data from a number of different sources. If you have questions about the sources of data in the Citation Index or need a set of data which is free to re-distribute, please contact us.

Certain data included herein are derived from the Web of Science© and InCites© (2024) of Clarivate Analytics. All rights reserved. You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.