Works (10)

Updated: October 23rd, 2023 08:15

2018 journal article

An FPGA-Based Backend System for Intravascular Photoacoustic and Ultrasound Imaging

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 66(1), 45–56.

By: X. Wu n, J. Sanders n, X. Zhang n, F. Yamaner n & O. Oralkan n

author keywords: Data acquisition; finite-state machine (FSM); field-programmable gate array (FPGA); photoacoustic (PA) imaging; software/hardware codesign; ultrasound (US) imaging; velocity measurement
MeSH headings : Algorithms; Equipment Design; Image Processing, Computer-Assisted / methods; Phantoms, Imaging; Photoacoustic Techniques / instrumentation; Photoacoustic Techniques / methods; Transducers; Ultrasonography, Interventional / instrumentation; Ultrasonography, Interventional / methods
TL;DR: A low-cost, compact, high-speed, and programmable imaging system based on a field-programmable gate array suitable for dual-mode forward-looking IVUS/IVPA imaging that provides a convenient backend platform for research and clinical IVPA and IVUS imaging. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Sources: Web Of Science, NC State University Libraries, ORCID
Added: February 18, 2019

2018 article

Summary of Advances in Heat-Pulse Methods: Measuring Near-Surface Soil Water Content

SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, Vol. 82, pp. 1015–1015.

By: X. Zhang*, T. Ren*, J. Heitman n & R. Horton*

UN Sustainable Development Goal Categories
6. Clean Water and Sanitation (OpenAlex)
Sources: Web Of Science, NC State University Libraries
Added: October 19, 2018

2016 conference paper

2D CMUT array based ultrasonic micromanipulation platform

2016 IEEE International Ultrasonics Symposium (IUS). Presented at the 2016 IEEE International Ultrasonics Symposium (IUS).

By: A. Zeshan*, X. Zhang n, O. Oralkan n & F. Yamaner*

Event: 2016 IEEE International Ultrasonics Symposium (IUS)

Sources: NC State University Libraries, Crossref, NC State University Libraries
Added: August 6, 2018

2016 conference paper

A MEMS T/R switch embedded in CMUT structure for ultrasound imaging frontends

2016 IEEE International Ultrasonics Symposium (IUS). Presented at the 2016 IEEE International Ultrasonics Symposium (IUS).

By: X. Zhang n, A. Zeshan*, O. Adelegan n, F. Yamaner* & O. Oralkan n

Event: 2016 IEEE International Ultrasonics Symposium (IUS)

UN Sustainable Development Goal Categories
7. Affordable and Clean Energy (OpenAlex)
Sources: NC State University Libraries, Crossref, NC State University Libraries
Added: August 6, 2018

2016 conference paper

CMUTs on glass with ITO bottom electrodes for improved transparency

2016 IEEE International Ultrasonics Symposium (IUS). Presented at the 2016 IEEE International Ultrasonics Symposium (IUS).

By: X. Zhang n, O. Adelegan n, F. Yamaner* & O. Oralkan n

Event: 2016 IEEE International Ultrasonics Symposium (IUS)

Sources: NC State University Libraries, Crossref, NC State University Libraries
Added: August 6, 2018

2016 journal article

Fabrication of Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducers With Through-Glass-Via Interconnects Using Anodic Bonding

Journal of Microelectromechanical Systems, 26(1), 226–234.

By: X. Zhang n, F. Yamaner* & O. Oralkan n

Sources: NC State University Libraries, Crossref, NC State University Libraries
Added: August 6, 2018

2015 journal article

A Three-Mask Process for Fabricating Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducers Using Anodic Bonding

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 62(5), 972–982.

By: F. Yamaner*, X. Zhang n & O. Oralkan n

MeSH headings : Electrodes; Equipment Design; Microtechnology; Models, Theoretical; Silicon Compounds / chemistry; Transducers; Ultrasonography / instrumentation; Vacuum
TL;DR: This paper introduces a simplified fabrication method for vacuum-sealed capacitive micromachined ultrasonic transducer arrays using anodic bonding, which combines the advantages of a patterned metal bottom electrode on an insulating substrate, specifically low parasitic series resistance and low parasitic shunt capacitance. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Sources: Web Of Science, NC State University Libraries
Added: August 6, 2018

2015 conference paper

Design of high-frequency broadband CMUT arrays

2015 IEEE International Ultrasonics Symposium (IUS). Presented at the 2015 IEEE International Ultrasonics Symposium (IUS).

By: X. Zhang n, F. Yamanery, O. Adelegan n & O. Oralkan n

Event: 2015 IEEE International Ultrasonics Symposium (IUS)

author keywords: High frequency transducer array; Broadband; CMUT; Anodic bonding; Glass
UN Sustainable Development Goal Categories
Sources: Web Of Science, Crossref, NC State University Libraries
Added: August 6, 2018

2015 conference paper

Fabrication of capacitive micromachined ultrasonic transducers with through-glass-via interconnects

2015 IEEE International Ultrasonics Symposium (IUS). Presented at the 2015 IEEE International Ultrasonics Symposium (IUS).

By: X. Zhang n, F. Yamanery & O. Oralkan n

Event: 2015 IEEE International Ultrasonics Symposium (IUS)

author keywords: CMUT; TGV; Anodic bonding; 3D integration; Glass
UN Sustainable Development Goal Categories
Sources: Web Of Science, Crossref, NC State University Libraries
Added: August 6, 2018

2014 article

Fabrication of Anodically Bonded Capacitive Micromachined Ultrasonic Transducers with Vacuum-Sealed Cavities

2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), pp. 604–607.

By: F. Yamaner n, X. Zhang n & O. Oralkan n

UN Sustainable Development Goal Categories
Sources: Web Of Science, NC State University Libraries
Added: August 6, 2018

Citation Index includes data from a number of different sources. If you have questions about the sources of data in the Citation Index or need a set of data which is free to re-distribute, please contact us.

Certain data included herein are derived from the Web of Science© and InCites© (2024) of Clarivate Analytics. All rights reserved. You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.