2019 journal article

Evaluation of the geometric accuracy of computed tomography and microcomputed tomography of the articular surface of the distal portion of the radius of cats

AMERICAN JOURNAL OF VETERINARY RESEARCH, 80(10), 976–984.

By: C. Webster n, D. Marcellin-Little n, E. Koballa n, J. Stallrich n & O. Harrysson n

MeSH headings : Animals; Cats / anatomy & histology; Humans; Radius / diagnostic imaging; Reproducibility of Results; X-Ray Microtomography / veterinary
TL;DR: Articular surface models derived from CT images had dimensional errors that approximately matched the voxel size and therefore CT cannot be used to plan conforming arthroplasties in small joints and could lack precision when use to plan the correction of a limb deformity or repair of a fracture. (via Semantic Scholar)
UN Sustainable Development Goal Categories
5. Gender Equality (Web of Science)
Source: Web Of Science
Added: April 20, 2020

Abstract OBJECTIVE To evaluate accuracy of articular surfaces determined by use of 2 perpendicular CT orientations, micro-CT, and laser scanning. SAMPLE 23 cat cadavers. PROCEDURES Images of antebrachia were obtained by use of CT (voxel size, 0.6 mm) in longitudinal orientation (CTLO images) and transverse orientation (CTTO images) and by use of micro-CT (voxel size, 0.024 mm) in a longitudinal orientation. Images were reconstructed. Craniocaudal and mediolateral length, radius of curvature, and deviation of the articular surface of the distal portion of the radius of 3-D renderings for CTLO, CTTO, and micro-CT images were compared with results of 3-D renderings acquired with a laser scanner (resolution, 0.025 mm). RESULTS Measurement of CTLO and CTTO images overestimated craniocaudal and mediolateral length of the articular surface by 4% to 10%. Measurement of micro-CT images underestimated craniocaudal and mediolateral length by 1%. Measurement of CTLO and CTTO images underestimated mediolateral radius of curvature by 15% and overestimated craniocaudal radius of curvature by > 100%; use of micro-CT images underestimated them by 3% and 5%, respectively. Mean ± SD surface deviation was 0.26 ± 0.09 mm for CTLO images, 0.30 ± 0.28 mm for CTTO images, and 0.04 ± 0.02 mm for micro-CT images. CONCLUSIONS AND CLINICAL RELEVANCE Articular surface models derived from CT images had dimensional errors that approximately matched the voxel size. Thus, CT cannot be used to plan conforming arthroplasties in small joints and could lack precision when used to plan the correction of a limb deformity or repair of a fracture.