Deep thrombosis characterization using photoacoustic imaging with intravascular light delivery

Tang, Y., Wu, H., Klippel, P., Zhang, B., Huang, H.-Y. S., Jing, Y., … Yao, J. (2022, February 16). BIOMEDICAL ENGINEERING LETTERS.

By: Y. Tang*, H. Wu n, P. Klippel*, B. Zhang n, H. Huang n, Y. Jing*, X. Jiang n, J. Yao*

author keywords: Thrombosis; Photoacoustic tomography; Internal light illumination; Photoacoustic frequency; Retracted blood clot; Unretracted blood clot; Blood oxygenation
TL;DR: The results show that, with intravascular light delivery, clot oxygenation level can be accurately measured, and the clot age can thus be estimated, and it is found that retracted and unretracted clots had different acoustic frequency spectrum. (via Semantic Scholar)
Source: Web Of Science
Added: March 7, 2022

Venous thromboembolism (VTE) is a condition in which blood clots form within the deep veins of the leg or pelvis to cause deep vein thrombosis. The optimal treatment of VTE is determined by thrombus properties such as the age, size, and chemical composition of the blood clots. The thrombus properties can be readily evaluated by using photoacoustic computed tomography (PACT), a hybrid imaging modality that combines the rich contrast of optical imaging and deep penetration of ultrasound imaging. With inherent sensitivity to endogenous chromophores such as hemoglobin, multispectral PACT can provide composition information and oxygenation level in the clots. However, conventional PACT of clots relies on external light illumination, which provides limited penetration depth due to strong optical scattering of intervening tissue. In our study, this depth limitation is overcome by using intravascular light delivery with a thin optical fiber. To demonstrate in vitro blood clot characterization, clots with different acuteness and oxygenation levels were placed underneath ten-centimeter-thick chicken breast tissue and imaged using multiple wavelengths. Acoustic frequency analysis was performed on the received PA channel signals, and oxygenation level was estimated using multispectral linear spectral unmixing. The results show that, with intravascular light delivery, clot oxygenation level can be accurately measured, and the clot age can thus be estimated. In addition, we found that retracted and unretracted clots had different acoustic frequency spectrum. While unretracted clots had stronger high frequency components, retracted clots had much higher low frequency components due to densely packed red blood cells. The PACT characterization of the clots was consistent with the histology results and mechanical tests.