2017 journal article

Development of a method for on-line determination of chlorine impurity in crude oil by using fast neutrons

FUEL, 209, 643–649.

co-author countries: Croatia 🇭🇷 Norway 🇳🇴 United States of America 🇺🇸
author keywords: DT neutron generator; PGNAA; CEARCPG; MCNP6; Crude oil; Chlorine
Source: Web Of Science
Added: August 6, 2018

An important challenge in the petroleum industry is to reduce the salt content to acceptable levels in crude oil. Continuous monitoring of crude oil salinity is thus an important aspect. However, development of safe and reliable on-line and non-intrusive monitoring systems is still a challenging task. In this work, a method for non-intrusive, on-line monitoring of the chlorine impurity in crude oil based on prompt gamma-ray neutron activation analysis (PGNAA) in conjunction with a portable pulsed neutron generator producing 14 MeV neutrons in deuterium-tritium (DT) nuclear reactions is proposed and tested. Simulations with Monte Carlo N-Particle version 6 (MCNP6) transport code combined with Center for Engineering Applications of Radioisotopes Detector Response Function (CEARDRF) and a specific purpose Monte Carlo code called Center for Engineering Applications of Radioisotopes Coincidence Prompt Gamma-Ray (CEARCPG) were used for the design optimization of the experiments. Preliminary results indicate that a minimum detection limit for chlorine impurity of about 71 mg/L is achievable for an integration time of 30 min.