Works (8)

Updated: July 5th, 2023 15:49

2012 journal article

AN IN VIVO VALIDATION OF THE APPLICATION OF ACOUSTIC RADIATION FORCE TO ENHANCE THE DIAGNOSTIC UTILITY OF MOLECULAR IMAGING USING 3-D ULTRASOUND

ULTRASOUND IN MEDICINE AND BIOLOGY, 38(4), 651–660.

By: R. Gessner n, J. Streeter n, R. Kothadia n, S. Feingold n & P. Dayton n

author keywords: Microbubble; Molecular imaging; Targeted imaging; Radiation force
MeSH headings : Animals; Contrast Media / administration & dosage; Contrast Media / chemical synthesis; Elasticity Imaging Techniques / methods; Equipment Design; Fibrosarcoma / diagnostic imaging; Fibrosarcoma / pathology; Image Enhancement / methods; Imaging, Three-Dimensional / methods; Microbubbles; Molecular Imaging / methods; Rats, Inbred F344; Sensitivity and Specificity; Transducers
TL;DR: This is the first noninvasive in vivo validation of ARF-enhanced MI with an unmodified clinical system and demonstrates that a 78% increase in image intensity from targeted microbubbles can be achieved when using ARF relative to the passive targeting studies. (via Semantic Scholar)
Source: Web Of Science
Added: August 6, 2018

2011 journal article

3-D MICROVESSEL-MIMICKING ULTRASOUND PHANTOMS PRODUCED WITH A SCANNING MOTION SYSTEM

ULTRASOUND IN MEDICINE AND BIOLOGY, 37(5), 827–833.

By: R. Gessner n, R. Kothadia n, S. Feingold n & P. Dayton n

author keywords: Phantom; Microbubble; Contrast; 3-D imaging; Vessel; Vessel network; Vessel architecture
MeSH headings : Artifacts; Biomimetic Materials; Contrast Media; Humans; Image Enhancement; Imaging, Three-Dimensional; Microvessels / diagnostic imaging; Motion; Sensitivity and Specificity; Ultrasonography / instrumentation; Ultrasonography / methods
TL;DR: A method to create predefined structures with <10 μm precision using a three-axis motion system is presented, which enables one to precisely simulate very slow blood flow and respiration artifacts, and to measure imaging resolution. (via Semantic Scholar)
UN Sustainable Development Goal Categories
14. Life Below Water (OpenAlex)
Source: Web Of Science
Added: August 6, 2018

2011 journal article

DECAFLUOROBUTANE AS A PHASE-CHANGE CONTRAST AGENT FOR LOW-ENERGY EXTRAVASCULAR ULTRASONIC IMAGING

ULTRASOUND IN MEDICINE AND BIOLOGY, 37(9), 1518–1530.

By: P. Sheeran n, V. Wong*, S. Luois*, R. McFarland*, W. Ross*, S. Feingold n, T. Matsunaga*, P. Dayton n

author keywords: Ultrasound; Microbubble; Contrast agent; Perfluorocarbon; Acoustic droplet vaporization
MeSH headings : Acoustics; Contrast Media / chemistry; Fluorocarbons / chemistry; Microbubbles; Microvessels; Nanoparticles / chemistry; Transducers; Ultrasonography / methods
TL;DR: It is shown that decafluorobutane, which is normally a gas at room temperature, can be incorporated into metastable liquid sub-micron droplets with appropriate encapsulation methods and are activatable with substantially less energy than other favored PCCA compounds. (via Semantic Scholar)
UN Sustainable Development Goal Categories
7. Affordable and Clean Energy (OpenAlex)
Source: Web Of Science
Added: August 6, 2018

2011 journal article

Effect and Distribution of Contrast Medium after Injection into the Anterior Suprachoroidal Space in Ex Vivo Eyes

Investigative Opthalmology & Visual Science, 52(8), 5730.

By: G. Seiler*, J. Salmon n, R. Mantuo n, S. Feingold n, P. Dayton n & B. Gilger n

MeSH headings : Age Factors; Animals; Anterior Chamber / diagnostic imaging; Anterior Chamber / metabolism; Choroid / diagnostic imaging; Choroid / metabolism; Contrast Media / pharmacokinetics; Dogs; Drug Delivery Systems; Imaging, Three-Dimensional; In Vitro Techniques; Injections, Intraocular / methods; Latex / pharmacokinetics; Microbubbles; Posterior Eye Segment / diagnostic imaging; Posterior Eye Segment / metabolism; Retina / diagnostic imaging; Retina / metabolism; Swine; Ultrasonography
TL;DR: The authors' hypothesis that a single anterior SCS injection can reach the ocular posterior segment was supported and it is suggested that the SCS can expand, in a dose-dependent manner, to accommodate various volumes of fluid and that it is possible to image theSCS with ultrasound contrast. (via Semantic Scholar)
Sources: Web Of Science, Crossref, ORCID
Added: August 6, 2018

2011 journal article

VALIDATION OF DYNAMIC CONTRAST-ENHANCED ULTRASOUND IN RODENT KIDNEYS AS AN ABSOLUTE QUANTITATIVE METHOD FOR MEASURING BLOOD PERFUSION

ULTRASOUND IN MEDICINE AND BIOLOGY, 37(6), 900–908.

By: P. Kogan, K. Johnson, S. Feingold*, N. Garrett, I. Guracar, W. Arendshorst, P. Dayton*

author keywords: Destruction-reperfusion; Flash replenishment; Microbubble; Contrast agent; Blood flow; Perfusion
MeSH headings : Animals; Blood Flow Velocity / physiology; Contrast Media; Image Enhancement / methods; Kidney / blood supply; Kidney / diagnostic imaging; Kidney / physiology; Male; Microbubbles; Perfusion Imaging / methods; Rats; Rats, Sprague-Dawley; Renal Circulation / physiology; Reproducibility of Results; Sensitivity and Specificity; Ultrasonography
TL;DR: Results indicate that there exists a range of contrast agent flow rates for which image-derived estimates are consistent, and differences in the sensitivity to flow across different transducer orientations as well as the contrast analysis algorithm utilized are reported. (via Semantic Scholar)
UN Sustainable Development Goal Categories
3. Good Health and Well-being (OpenAlex)
Source: Web Of Science
Added: August 6, 2018

2010 journal article

Quantitative Volumetric Perfusion Mapping of the Microvasculature Using Contrast Ultrasound

INVESTIGATIVE RADIOLOGY, 45(10), 669–674.

By: S. Feingold n, R. Gessner*, I. Guracar* & P. Dayton*

author keywords: perfusion; microbubble; 3D; parametric; ultrasound
MeSH headings : Algorithms; Animals; Contrast Media; Feasibility Studies; Hemodynamics; Kidney / blood supply; Kidney / diagnostic imaging; Microvessels / diagnostic imaging; Models, Animal; Perfusion Imaging / instrumentation; Perfusion Imaging / methods; Rats; Rats, Sprague-Dawley; Ultrasonography / instrumentation; Ultrasonography / methods
TL;DR: Three-dimensional perfusion imaging allows a significant reduction in the error caused by transducer positioning, and significantly improves the reliability of quantitative perfusion time estimates in a rat kidney model. (via Semantic Scholar)
Source: Web Of Science
Added: August 6, 2018

2009 article

Controllable Microfluidic Synthesis of Multiphase Drug-Carrying Lipospheres for Site-Targeted Therapy

BIOTECHNOLOGY PROGRESS, Vol. 25, pp. 938–945.

author keywords: cancer; drug delivery; liposome; microbubble; microfluidics
MeSH headings : Cell Line, Tumor; Chemistry, Pharmaceutical; Drug Carriers / chemical synthesis; Drug Carriers / chemistry; Drug Delivery Systems / methods; Humans; Lipids / chemistry; Microfluidics / methods; Oils / chemistry; Particle Size; Phase Transition
TL;DR: The production of micrometer‐sized gas‐filled lipospheres using digital (droplet‐based) microfluidics technology for chemotherapeutic drug delivery and preliminary acoustic studies reveal a highly uniform echo correlation of greater than 95%. (via Semantic Scholar)
Source: Web Of Science
Added: August 6, 2018

journal article

Assessment of molecular imaging of angiogenesis with three-dimensional ultrasonography

Streeter, J. E., Gessner, R. C., Tsuruta, J., Feingold, S., & Dayton, P. A. Molecular Imaging, 10(6), 460–468.

By: J. Streeter, R. Gessner, J. Tsuruta, S. Feingold & P. Dayton

Source: NC State University Libraries
Added: August 6, 2018

Citation Index includes data from a number of different sources. If you have questions about the sources of data in the Citation Index or need a set of data which is free to re-distribute, please contact us.

Certain data included herein are derived from the Web of Science© and InCites© (2024) of Clarivate Analytics. All rights reserved. You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.