Works (27)

2019 journal article

Candle-Soot Carbon Nanoparticles in Photoacoustics Advantages and challenges for laser ultrasound transmitters

IEEE NANOTECHNOLOGY MAGAZINE, 13(3), 13–28.

Source: Web Of Science
Added: June 17, 2019

2018 journal article

A Dual-Frequency Colinear Array for Acoustic Angiography in Prostate Cancer Evaluation

IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 65(12), 2418–2428.

By: S. Li, J. Kim, Z. Wang, S. Kasoji, B. Lindsey, P. Dayton, X. Jiang

Source: NC State University Libraries
Added: January 14, 2019

2018 conference paper

Miniaturized focused ultrasound transducers for intravascular therapies

In Proceedings of the ASME International Mechanical Engineering Congress and Exposition, 2017, vol 3.

By: J. Kim, H. Wu & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2017 journal article

Dual-frequency piezoelectric endoscopic transducer for imaging vascular invasion in pancreatic cancer

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 64(7), 1078–1086.

By: B. Lindsey, J. Kim, P. Dayton & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2017 conference paper

Dual-frequency transducer with a wideband PVDF receiver for contrast-enhanced, adjustable harmonic imaging

In Health monitoring of structural and biological systems 2017 (Vol. 10170).

By: J. Kim, B. Lindsey, S. Li, P. Dayton & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2017 book

High frequency piezo-composite micromachined ultrasound transducer array technology for biomedical imaging

New York, NY, USA: ASME Press.

By: X. Jiang, S. Li, J. Kim & J. Ma

Source: NC State University Libraries
Added: August 6, 2018

2017 conference paper

High temperature transducer using aluminum nitride single crystal for laser ultrasound detection

In Nondestructive characterization and monitoring of advanced materials, aerospace, and civil infrastructure 2017 (Vol. 10169).

By: T. Kim, J. Kim & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2017 journal article

Intravascular forward-looking ultrasound transducers for microbubble-mediated sonothrombolysis

Scientific Reports, 7.

By: J. Kim, B. Lindsey, W. Chang, X. Dai, J. Stavas, P. Dayton, X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2017 journal article

Piezoelectric floating element shear stress sensor for the wind tunnel flow measurement

IEEE Transactions on Industrial Electronics, 64(9), 7304–7312.

By: T. Kim, A. Saini, J. Kim, A. Gopalarathnam, Y. Zhu, F. Palmieri, C. Wohl, X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2017 journal article

Transit time difference flowmeter for intravenous flow rate measurement using 1-3 piezoelectric composite transducers

IEEE Sensors Journal, 17(17), 5741–5748.

By: T. Kim, J. Kim & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2016 conference paper

A dual-frequency co-linear array for prostate acoustic angiography

In 2016 ieee international ultrasonics symposium (ius).

By: S. Li, J. Kim, Z. Wang, X. Jiang, S. Kasoji, B. Lindsey, P. Dayton

Source: NC State University Libraries
Added: August 6, 2018

2016 conference paper

A dual-frequency endoscopic transducer for imaging vascular invasion in pancreatic cancer

In 2016 ieee international ultrasonics symposium (ius).

By: B. Lindsey, P. Dayton, J. Kim & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2016 journal article

A novel laser ultrasound transducer using candle soot carbon nanoparticles

IEEE Transactions on Nanotechnology, 15(3), 395–401.

By: W. Huang, W. Chang, J. Kim, S. Li, S. Huang & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2016 journal article

A novel ultrasound technique for non-invasive assessment of cell differentiation

IEEE Sensors Journal, 16(1), 61–68.

By: W. Huang, J. Kim, K. Kim, S. Bakshi, J. Williams, P. Matthieu, E. Loboa, K. Shung, Q. Zhou, X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2016 conference paper

A piezoelectric shear stress sensor

In Sensors and smart structures technologies for civil, mechanical, and aerospace systems 2016 (Vol. 9803).

By: T. Kim, A. Saini, J. Kim, A. Gopalarathnam, Y. Zhu, F. Palmieri, C. Wohl, X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2016 conference paper

Laser-generated-focused ultrasound transducers for microbubble-mediated, dual-excitation sonothrombolysis

In 2016 ieee international ultrasonics symposium (ius).

By: J. Kim, W. Chang, B. Lindsey, P. Dayton, X. Dai, J. Stavas, X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2016 conference paper

Nanocomposite transducer with a laser ultarsound transmitter and a piezoelectric receiver

In 2016 IEEE 16th International Conference on Nanotechnology (IEEE-nano) (pp. 191–192).

By: J. Kim, W. Chang, S. Huang & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

A 3 MHz/18 MHz dual-layer co-linear array for transrectal acoustic angiography

In 2015 ieee international ultrasonics symposium (ius).

By: S. Li, J. Kim, Z. Wang, X. Jiang, S. Kasoji, B. Lindsey, P. Dayton

Source: NC State University Libraries
Added: August 6, 2018

2015 journal article

A laser ultrasound transducer using carbon nanofibers-polydimethylsiloxane composite thin film

Applied Physics Letters, 106(2).

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

A novel laser ultrasound transducer using candle soot carbon nanoparticles

In 2015 IEEE 15th International Conference on Nanotechnology (IEEE-NANO) (pp. 1243–1246).

By: W. Chang, J. Kim, S. Li, W. Huang & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2015 journal article

Candle soot nanoparticles-polydimethylsiloxane composites for laser ultrasound transducers

Applied Physics Letters, 107(16).

By: W. Chang, W. Huang, J. Kim, S. Li & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

Dual-frequency super harmonic imaging piezoelectric transducers for transrectal ultrasound

In Health monitoring of structural and biological systems 2015 (Vol. 9438).

By: J. Kim, S. Li, S. Kasoji, P. Dayton & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2015 journal article

High-temperature electromechanical characterization of AlN single crystals

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control, 62(10), 1880–1887.

By: T. Kim, J. Kim, R. Dalmau, R. Schlesser, E. Preble & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2015 journal article

Phantom evaluation of stacked-type dual-frequency 1-3 composite transducers: A feasibility study on intracavitary acoustic angiography

Ultrasonics, 63, 7–15.

By: J. Kim, S. Li, S. Kasoji, P. Dayton & X. Jiang

Source: NC State University Libraries
Added: August 6, 2018

2015 journal article

Spatiotemporal drug delivery using laser-generated-focused ultrasound system

Journal of Controlled Release, 220, 592–599.

By: J. Di, J. Kim, Q. Hu, X. Jiang & Z. Gu

Source: NC State University Libraries
Added: August 6, 2018

2014 conference paper

Development of transmitters in dual-frequency transducers for interventional contrast enhanced imaging and acoustic angiography

In 2014 IEEE International Ultrasonics Symposium (IUS) (pp. 679–682).

By: J. Kim, S. Li, X. Jiang, S. Kasoji & P. Dayton

Source: NC State University Libraries
Added: August 6, 2018

review

Relaxor-PT single crystal piezoelectric sensors

Jiang, X. N., Kim, J., & Kim, K. Crystals.

By: X. Jiang, J. Kim & K. Kim

Source: NC State University Libraries
Added: August 6, 2018