2024 journal article
Design, Fabrication, and Characterization of Capacitive Micromachined Ultrasonic Transducers for Transcranial, Multifocus Neurostimulation
Micromachines, 15(9), 1106.
2024 article
Fabrication of 32 x 32 2D CMUT Arrays on a Borosilicate Glass Substrate With Silicon-Through-Wafer Interconnects Using Non-Aligned and Aligned Anodic Bonding
Annayev, M., Biliroglu, A. O., Sennik, E., Yamaner, F. Y., & Oralkan, O. (2024, August 22). JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, Vol. 8.
2023 journal article
Activation of primate frontal eye fields with a CMUT phased array system
JOURNAL OF NEUROSCIENCE METHODS, 402.
2023 journal article
Deep-Learning-Based High-Intensity Focused Ultrasound Lesion Segmentation in Multi-Wavelength Photoacoustic Imaging
BIOENGINEERING-BASEL, 10(9).
2023 journal article
Design and Fabrication of 1-D CMUT Arrays for Dual-Mode Dual-Frequency Acoustic Angiography Applications
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 71(1), 191–201.
2023 article
Performance of A Monolithic E-Nose Array Integrating MEMS and ALD Processing
2023 IEEE SENSORS.
2023 journal article
Photoacoustic imaging of visually evoked cortical and subcortical hemodynamic activity in mouse brain: feasibility study with piezoelectric and capacitive micromachined ultrasonic transducer (CMUT) arrays
BIOMEDICAL OPTICS EXPRESS, 14(12), 6283–6290.
2023 article
Plant Disease Detection Using an Electronic Nose
2023 IEEE SENSORS.
2022 journal article
A Handheld Imaging Probe for Acoustic Angiography With an Ultrawideband Capacitive Micromachined Ultrasonic Transducer (CMUT) Array
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 69(7), 2318–2330.
2022 article
A pre-charged CMUT structure with a built-in charge storage capacitor
2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS).
2022 journal article
An Ultrasonic Energy Harvesting IC Providing Adjustable Bias Voltage for Pre-Charged CMUT
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 16(5), 842–851.
2022 article
Performance Assessment of Ultra-Wideband and Dual-Mode 1D CMUT Arrays for Acoustic Angiography
2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS).
2021 journal article
A Low-Power Wearable E-Nose System Based on a Capacitive Micromachined Ultrasonic Transducer (CMUT) Array for Indoor VOC Monitoring
IEEE Sensors Journal, 21(18), 19684–19696.
2021 journal article
A Wearable Ultrasonic Neurostimulator-Part I: A 1D CMUT Phased Array System for Chronic Implantation in Small Animals
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 15(4), 692–704.
2021 journal article
A Wearable Ultrasonic Neurostimulator-Part II: A 2D CMUT Phased Array System With a Flip-Chip Bonded ASIC
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 15(4), 705–718.
2021 article
Design and Fabrication of 1D CMUT Arrays for Dual-Mode Acoustic Angiography Applications - Preliminary Results
INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021).
2021 article proceedings
Design and Fabrication of Single-Element CMUTs for Forming a Transcranial Array for Focused Beam Applications
Event: 2021 IEEE International Ultrasonics Symposium (IUS)
2021 journal article
Design and Fabrication of Wideband Air-Coupled Capacitive Micromachined Ultrasonic Transducers With Varying Width Annular-Ring and Spiral Cell Structures
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 68(8), 2749–2759.
2021 article
Design of Pre-Charged CMUTs with a Metal Floating Gate
INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021).
2021 journal article
Electronic nose system based on a functionalized capacitive micromachined ultrasonic transducer (CMUT) array for selective detection of plant volatiles
SENSORS AND ACTUATORS B-CHEMICAL, 341.
2021 journal article
Entrainment of cerebellar Purkinje cell spiking activity using pulsed ultrasound stimulation
BRAIN STIMULATION, 14(3), 598–606.
2021 journal article
Fabrication of 32 x 32 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Arrays on a Borosilicate Glass Substrate With Silicon-Through-Wafer Interconnects Using Sacrificial Release Process
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 30(6), 968–979.
2021 journal article
Soybean Cyst Nematodes Influence Aboveground Plant Volatile Signals Prior to Symptom Development
FRONTIERS IN PLANT SCIENCE, 12.
2021 journal article
Transcranial Neuromodulation Array With Imaging Aperture for Simultaneous Multifocus Stimulation in Nonhuman Primates
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 69(1), 261–272.
2020 article
A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate
Sanders, J. L., Biliroglu, A. O., Wu, X., Adelegan, O. J., Yamaner, F. Y., & Oralkan, O. (2021, March). IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, Vol. 68, pp. 767–776.
2020 journal article
An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 67(11), 2291–2302.
2020 review
Editors' Choice-Critical Review-A Critical Review of Solid State Gas Sensors
[Review of ]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 167(3).
2020 journal article
Fabrication of 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Arrays on Insulating Substrates With Through-Wafer Interconnects Using Sacrificial Release Process
Journal of Microelectromechanical Systems, 29(4), 553–561.
2020 article
Guest Editorial Special Issue on Selected Papers From the IEEE Sensors Conference 2018
Dahiya, R., Oralkan, O., & Pratap, R. (2020, July 1). IEEE SENSORS JOURNAL, Vol. 20, pp. 6792–6793.
2019 journal article
A Low-Power Wireless Multichannel Gas Sensing System Based on a Capacitive Micromachined Ultrasonic Transducer (CMUT) Array
IEEE INTERNET OF THINGS JOURNAL, 6(1), 831–843.
2018 conference paper
A CMUT - Based Electronic Nose for Real- Time Monitoring of Volatiles Emitted by Plants: Preliminary Results
2018 IEEE SENSORS. Presented at the 2018 IEEE Sensors.
Event: 2018 IEEE Sensors
2018 journal article
A Fast-Switching (1.35-mu s) Low-Control-Voltage (2.5-V) MEMS T/R Switch Monolithically Integrated With a Capacitive Micromachined Ultrasonic Transducer
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 27(2), 190–200.
2018 conference paper
A Row-Column (RC) Addressed 2D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate: Preliminary Results
2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Presented at the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).
Event: 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
2018 journal article
An FPGA-Based Backend System for Intravascular Photoacoustic and Ultrasound Imaging
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 66(1), 45–56.
2018 conference paper
Design and Fabrication of High-Frequency Ultra-Wideband 1D CMUT Arrays for Acoustic Angiography Applications - Preliminary Results
2018 IEEE International Ultrasonics Symposium (IUS). Presented at the 2018 IEEE International Ultrasonics Symposium (IUS).
Event: 2018 IEEE International Ultrasonics Symposium (IUS)
2018 conference paper
Design and Implementation of Wideband CMUTs for Airborne Applications - Preliminary Results
2018 IEEE International Ultrasonics Symposium (IUS). Presented at the 2018 IEEE International Ultrasonics Symposium (IUS).
Event: 2018 IEEE International Ultrasonics Symposium (IUS)
2018 conference paper
Towards an Untethered Ultrasound Beamforming System for Brain Stimulation in Behaving Animals
2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Presented at the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).
Event: 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
2017 conference paper
A front-end integrated circuit for a 2D capacitive micromachined ultrasound transducer (CMUT) array as a noninvasive neural stimulator
2017 IEEE International Ultrasonics Symposium (IUS). Presented at the 2017 IEEE International Ultrasonics Symposium (IUS).
Event: 2017 IEEE International Ultrasonics Symposium (IUS)
2017 conference paper
A handheld 1D transparent CMUT array probe for photoacoustic imaging: Preliminary results
2017 IEEE International Ultrasonics Symposium (IUS). Presented at the 2017 IEEE International Ultrasonics Symposium (IUS).
Event: 2017 IEEE International Ultrasonics Symposium (IUS)
2017 conference paper
A high-frequency and high-frame-rate ultrasound imaging system design on an FPGA evaluation board for capacitive micromachined ultrasonic transducer arrays
2017 IEEE International Ultrasonics Symposium (IUS). Presented at the 2017 IEEE International Ultrasonics Symposium (IUS).
Event: 2017 IEEE International Ultrasonics Symposium (IUS)
2017 conference paper
Adaptation of the acoustic angiography technique for use with a capacitive micromachined ultrasound transducer (CMUT)
2017 IEEE International Ultrasonics Symposium (IUS). Presented at the 2017 IEEE International Ultrasonics Symposium (IUS).
Event: 2017 IEEE International Ultrasonics Symposium (IUS)
2017 conference paper
An optically transparent capacitive micromachined ultrasonic transducer (CMUT) fabricated using SU-8 or BCB adhesive wafer bonding
2017 IEEE International Ultrasonics Symposium (IUS). Presented at the 2017 IEEE International Ultrasonics Symposium (IUS).
Event: 2017 IEEE International Ultrasonics Symposium (IUS)
2017 journal article
Backward-Mode Photoacoustic Imaging Using Illumination Through a CMUT With Improved Transparency
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 65(1), 85–94.
2017 conference paper
Gravimetric biosensor based on a capacitive micromachined ultrasonic transducer functionalized with peptide ligands
2017 IEEE SENSORS. Presented at the 2017 IEEE SENSORS.
Event: 2017 IEEE SENSORS
2017 conference paper
Improved CMUT structure and method of operation for dual-frequency acoustic angiography
2017 IEEE International Ultrasonics Symposium (IUS). Presented at the 2017 IEEE International Ultrasonics Symposium (IUS).
Event: 2017 IEEE International Ultrasonics Symposium (IUS)
2017 conference paper
Integration of a dual-mode catheter for ultrasound image guidance and HIFU ablation using a 2-D CMUT array
2017 IEEE International Ultrasonics Symposium (IUS). Presented at the 2017 IEEE International Ultrasonics Symposium (IUS).
Event: 2017 IEEE International Ultrasonics Symposium (IUS)
2017 conference paper
Multi-wavelength photoacoustic imaging for monitoring lesion formation during high-intensity focused ultrasound therapy
Photons plus ultrasound: imaging and sensing 2017, 10064.
2016 conference paper
2D CMUT array based ultrasonic micromanipulation platform
2016 IEEE International Ultrasonics Symposium (IUS). Presented at the 2016 IEEE International Ultrasonics Symposium (IUS).
Event: 2016 IEEE International Ultrasonics Symposium (IUS)
2016 conference paper
A MEMS T/R switch embedded in CMUT structure for ultrasound imaging frontends
2016 IEEE International Ultrasonics Symposium (IUS). Presented at the 2016 IEEE International Ultrasonics Symposium (IUS).
Event: 2016 IEEE International Ultrasonics Symposium (IUS)
2016 conference paper
A battery-operated wireless multichannel gas sensor system based on a capacitive micromachined ultrasonic transducer (CMUT) array
2016 ieee sensors.
2016 conference paper
CMUTs on glass with ITO bottom electrodes for improved transparency
2016 IEEE International Ultrasonics Symposium (IUS). Presented at the 2016 IEEE International Ultrasonics Symposium (IUS).
Event: 2016 IEEE International Ultrasonics Symposium (IUS)
2016 journal article
Fabrication of Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducers With Through-Glass-Via Interconnects Using Anodic Bonding
Journal of Microelectromechanical Systems, 26(1), 226–234.
2016 journal article
Low-Power Wearable Systems for Continuous Monitoring of Environment and Health for Chronic Respiratory Disease
IEEE Journal of Biomedical and Health Informatics, 20(5), 1251–1264.
2016 conference paper
Photoacoustic-imaging-based temperature monitoring for high-intensity focused ultrasound therapy
2016 38th annual international conference of the ieee engineering in medicine and biology society (embc), 3235–3238.
2016 journal article
Wideband acoustic activation and detection of droplet vaporization events using a capacitive micromachined ultrasonic transducer
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 139(6), 3193–3198.
2015 journal article
A Three-Mask Process for Fabricating Vacuum-Sealed Capacitive Micromachined Ultrasonic Transducers Using Anodic Bonding
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 62(5), 972–982.
2015 conference paper
A capacitive micromachined ultrasonic transducer (CMUT) array as a low-power multi-channel volatile organic compound (VOC) sensor
2015 ieee sensors, 181–184.
2015 conference paper
A low-power integrated circuit for interfacing a capacitive micromachined ultrasonic transducer (CMUT) based resonant gas sensor
2015 ieee sensors, 1781–1784.
2015 conference paper
Design of high-frequency broadband CMUT arrays
2015 IEEE International Ultrasonics Symposium (IUS). Presented at the 2015 IEEE International Ultrasonics Symposium (IUS).
Event: 2015 IEEE International Ultrasonics Symposium (IUS)
2015 article
Dual-Mode Integrated Circuit for Imaging and HIFU With 2-D CMUT Arrays
2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS).
2015 conference paper
Fabrication of capacitive micromachined ultrasonic transducers with through-glass-via interconnects
2015 IEEE International Ultrasonics Symposium (IUS). Presented at the 2015 IEEE International Ultrasonics Symposium (IUS).
Event: 2015 IEEE International Ultrasonics Symposium (IUS)
2015 journal article
Flexible Technologies for Self-Powered Wearable Health and Environmental Sensing
PROCEEDINGS OF THE IEEE, 103(4), 665–681.
2015 conference paper
Self-powered wearable sensor platforms for wellness
2015 International Conference on Compilers, Architecture and Synthesis for Embedded Systems (CASES), 187–187.
2014 journal article
A Multichannel Oscillator for a Resonant Chemical Sensor System
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 61(10), 5632–5640.
2014 conference paper
A low-power gas sensor for environmental monitoring using a capacitive micromachined ultrasonic transducer
IEEE SENSORS 2014 Proceedings. Presented at the 2014 IEEE Sensors.
Event: 2014 IEEE Sensors
2014 article
An Ultrasound-Based Noninvasive Neural Interface to the Retina Projection Algorithm and Frontend Integrated Circuit Architecture
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), pp. 2623–2626.
2014 article
Fabrication of Anodically Bonded Capacitive Micromachined Ultrasonic Transducers with Vacuum-Sealed Cavities
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), pp. 604–607.
2013 conference paper
3D volumetric ultrasound imaging with a 32×32 CMUT array integrated with front-end ICs using flip-chip bonding technology
2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers. Presented at the 2013 IEEE International Solid-State Circuits Conference (ISSCC 2013).
Event: 2013 IEEE International Solid-State Circuits Conference (ISSCC 2013)
2013 conference paper
A 32×32 integrated CMUT array for volumetric ultrasound imaging
2013 IEEE International Ultrasonics Symposium (IUS). Presented at the 2013 IEEE International Ultrasonics Symposium (IUS).
Event: 2013 IEEE International Ultrasonics Symposium (IUS)
2013 journal article
A comparison between conventional and collapse-mode capacitive micromachined ultrasonic transducers in 10-MHz 1-D arrays
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 60(6), 1245–1255.
2013 journal article
Dynamic Response of Model Lipid Membranes to Ultrasonic Radiation Force
PLoS ONE, 8(10), e77115.
Ed(s): W. Phillips
2013 journal article
GPU-Based Real-Time Volumetric Ultrasound Image Reconstruction for a Ring Array
IEEE Transactions on Medical Imaging, 32(7), 1258–1264.
2013 conference paper
GPU-based real-time imaging software suite for medical ultrasound
2013 IEEE International Ultrasonics Symposium (IUS). Presented at the 2013 IEEE International Ultrasonics Symposium (IUS).
Event: 2013 IEEE International Ultrasonics Symposium (IUS)
2013 chapter
Innovations in Ultrasound Instrumentation for Image Guidance
In Intraoperative Imaging and Image-Guided Therapy (pp. 163–171).
2013 article
Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays
Bhuyan, A., Choe, J. W., Lee, B. C., Wygant, I. O., Nikoozadeh, A., Oralkan, O., & Khuri-Yakub, B. T. (2013, December). IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, Vol. 7, pp. 796–804.
2013 journal article
Photoacoustic Imaging of the Bladder A Pilot Study
JOURNAL OF ULTRASOUND IN MEDICINE, 32(7), 1245–1250.
2013 journal article
Precise Neural Stimulation in the Retina Using Focused Ultrasound
Journal of Neuroscience, 33(10), 4550–4560.
2012 journal article
Deep Tissue Photoacoustic Imaging Using a Miniaturized 2-D Capacitive Micromachined Ultrasonic Transducer Array
IEEE Transactions on Biomedical Engineering, 59(5), 1199–1204.
2012 journal article
First In Vivo Use of a Capacitive Micromachined Ultrasound Transducer Array-Based Imaging and Ablation Catheter
Journal of Ultrasound in Medicine, 31(2), 247–256.
2012 conference paper
Photoacoustic imaging using a 9F microLinear CMUT ICE catheter
2012 IEEE International Ultrasonics Symposium. Presented at the 2012 IEEE International Ultrasonics Symposium.
Event: 2012 IEEE International Ultrasonics Symposium
2012 journal article
Ultrasound-Induced Currents in Planar Lipid Blayers: Origins and Potential Physiological Significance
Biophysical Journal, 102(3), 34a.
2012 journal article
Volumetric real-time imaging using a CMUT ring array
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 59(6), 1201–1211.
2011 journal article
Capacitive micromachined ultrasonic transducer (CMUT) as a chemical sensor for DMMP detection
Sensors and Actuators B: Chemical, 160(1), 1120–1127.
2011 journal article
Capacitive micromachined ultrasonic transducers for medical imaging and therapy
Journal of Micromechanics and Microengineering, 21(5), 054004.
2011 journal article
Chemical Vapor Detection Using a Capacitive Micromachined Ultrasonic Transducer
Analytical Chemistry, 83(24), 9314–9320.
2011 conference paper
Comparison of conventional and collapse-mode CMUT in 1-D array configuration
2011 IEEE International Ultrasonics Symposium. Presented at the 2011 IEEE International Ultrasonics Symposium (IUS).
Event: 2011 IEEE International Ultrasonics Symposium (IUS)
2011 conference paper
Interdigitated annular CMUT arrays for ultrasound assisted delivery of fluorescent contrast agents
2011 IEEE International Ultrasonics Symposium. Presented at the 2011 IEEE International Ultrasonics Symposium (IUS).
Event: 2011 IEEE International Ultrasonics Symposium (IUS)
2011 chapter
Intracardiac Forward-Looking Ultrasound Imaging Catheters Using Capacitive Micromachined Ultrasonic Transducers
In Acoustical Imaging (pp. 203–210).
2011 conference paper
Miniaturized, wearable, ultrasound probe for on-demand ultrasound screening
2011 IEEE International Ultrasonics Symposium. Presented at the 2011 IEEE International Ultrasonics Symposium (IUS).
Event: 2011 IEEE International Ultrasonics Symposium (IUS)
2011 conference paper
Real-time volumetric imaging system for CMUT arrays
2011 IEEE International Ultrasonics Symposium. Presented at the 2011 IEEE International Ultrasonics Symposium (IUS).
Event: 2011 IEEE International Ultrasonics Symposium (IUS)
2011 conference paper
Regulating energy delivery during intracardiac radiofrequency ablation using thermal strain imaging
2011 IEEE International Ultrasonics Symposium. Presented at the 2011 IEEE International Ultrasonics Symposium (IUS).
Event: 2011 IEEE International Ultrasonics Symposium (IUS)
2011 journal article
The feasibility of using thermal strain imaging to regulate energy delivery during intracardiac radio-frequency ablation
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 58(7), 1406–1417.
2011 conference paper
Volumetric intracardiac imaging using a fully integrated CMUT ring array: Recent developments
2011 IEEE International Ultrasonics Symposium. Presented at the 2011 IEEE International Ultrasonics Symposium (IUS).
Event: 2011 IEEE International Ultrasonics Symposium (IUS)
2010 conference paper
3-D Deep penetration photoacoustic imaging with a 2-D CMUT array
2010 IEEE International Ultrasonics Symposium. Presented at the 2010 IEEE Ultrasonics Symposium (IUS).
Event: 2010 IEEE Ultrasonics Symposium (IUS)
2010 conference paper
Design optimization for a 2-D sparse transducer array for 3-D ultrasound imaging
2010 IEEE International Ultrasonics Symposium. Presented at the 2010 IEEE Ultrasonics Symposium (IUS).
Event: 2010 IEEE Ultrasonics Symposium (IUS)
2010 conference paper
Forward-looking intracardiac imaging catheters using fully integrated CMUT arrays
2010 IEEE International Ultrasonics Symposium. Presented at the 2010 IEEE Ultrasonics Symposium (IUS).
Event: 2010 IEEE Ultrasonics Symposium (IUS)
2010 conference paper
Highly sensitive detection of DMMP using a CMUT-based chemical sensor
2010 IEEE Sensors. Presented at the 2010 Ninth IEEE Sensors Conference (SENSORS 2010).
Event: 2010 Ninth IEEE Sensors Conference (SENSORS 2010)
2010 conference paper
Miniaturized ultrasound imaging probes enabled by CMUT arrays with integrated frontend electronic circuits
2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. Presented at the 2010 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2010).
Event: 2010 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2010)
2010 conference paper
Monitoring radiofrequency catheter ablation using thermal strain imaging
2010 IEEE International Ultrasonics Symposium. Presented at the 2010 IEEE Ultrasonics Symposium (IUS).
Event: 2010 IEEE Ultrasonics Symposium (IUS)
2010 conference paper
Packaging of large and low-pitch size 2D ultrasonic transducer arrays
Proceedings of the 2010 IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), 508–511.
Event: 23rd IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2010)
2010 conference paper
Simulating capacitive micromachined ultrasonic transducers (CMUTs) using field II
2010 IEEE International Ultrasonics Symposium. Presented at the 2010 International Ultrasonics Symposium.
Event: 2010 International Ultrasonics Symposium
2010 conference paper
Ultrasound compatible RF ablation electrode design for catheter based guidance of RF ablation — In vivo results with thermal strain imaging
2010 IEEE International Ultrasonics Symposium. Presented at the 2010 International Ultrasonics Symposium.
Event: 2010 International Ultrasonics Symposium
2010 conference paper
Zero-bias resonant sensor with an oxide-nitride layer as charge trap
2010 IEEE Sensors. Presented at the 2010 Ninth IEEE Sensors Conference (SENSORS 2010).
Event: 2010 Ninth IEEE Sensors Conference (SENSORS 2010)
2009 conference paper
A 2D CMUT hydrophone array: Characterization results
2009 IEEE International Ultrasonics Symposium. Presented at the 2009 IEEE International Ultrasonics Symposium.
Event: 2009 IEEE International Ultrasonics Symposium
2009 conference paper
A Low-Noise Oscillator based on a Multi-Membrane CMUT for High Sensitivity Resonant Chemical Sensors
2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems. Presented at the 2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems (MEMS).
Event: 2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems (MEMS)
2009 conference paper
A family of intracardiac ultrasound imaging devices designed for guidance of electrophysiology ablation procedures
2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Presented at the 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
Event: 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
2009 journal article
An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 56(10), 2145–2156.
2009 conference paper
Challenges of solder bumping capacitive micro-machined ultrasonic transducer (cMUT) trenched devices
Proceedings of SMTA International Conference & Exhibition, 1–11.
2009 conference paper
Enhanced sensitivity carbon nanotubes as targeted photoacoustic molecular imaging agents
In A. A. Oraevsky & L. V. Wang (Eds.), Photons Plus Ultrasound: Imaging and Sensing 2009.
Ed(s): A. Oraevsky & L. Wang
Event: SPIE BiOS: Biomedical Optics
2009 journal article
Experimental Studies With a 9F Forward-Looking Intracardiac Imaging and Ablation Catheter
Journal of Ultrasound in Medicine, 28(2), 207–215.
2009 conference paper
Forward-looking volumetric intracardiac imaging using a fully integrated CMUT ring array
2009 IEEE International Ultrasonics Symposium. Presented at the 2009 IEEE International Ultrasonics Symposium.
Event: 2009 IEEE International Ultrasonics Symposium
2009 journal article
Minimally Redundant 2-D Array Designs for 3-D Medical Ultrasound Imaging
IEEE Transactions on Medical Imaging, 28(7), 1051–1061.
2009 conference paper
Multi-row linear cMUT array using cMUTs and multiplexing electronics
2009 IEEE International Ultrasonics Symposium. Presented at the 2009 IEEE International Ultrasonics Symposium.
Event: 2009 IEEE International Ultrasonics Symposium
2009 journal article
Next-gen ultrasound
IEEE Spectrum, 46(5), 44–54.
2009 conference paper
Photoacoustic molecular imaging using single walled carbon nanotubes in living mice
In A. A. Oraevsky & L. V. Wang (Eds.), Photons Plus Ultrasound: Imaging and Sensing 2009.
Ed(s): A. Oraevsky & L. Wang
Event: SPIE BiOS: Biomedical Optics
2009 journal article
Three-dimensional photoacoustic imaging using a two-dimensional CMUT array
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 56(11), 2411–2419.
2009 journal article
Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 56(1), 182–192.
2008 conference paper
CMUT as a chemical sensor for DMMP detection
2008 IEEE International Frequency Control Symposium. Presented at the 2008 IEEE International Frequency Control Symposium.
Event: 2008 IEEE International Frequency Control Symposium
2008 conference paper
Capacitive micromachined ultrasonic transducer as a chemical sensor
2008 IEEE Sensors. Presented at the 2008 IEEE Sensors.
Event: 2008 IEEE Sensors
2008 journal article
Carbon nanotubes as photoacoustic molecular imaging agents in living mice
Nature Nanotechnology, 3(9), 557–562.
2008 conference paper
Development of nanoparticle-based gold contrast agent for photoacoustic tomography
Technical Proceedings of NSTI Nanotech, 1, 708–711.
2008 conference paper
Fabricating capacitive micromachined ultrasonic transducers with direct wafer-bonding and LOCOS technology
2008 IEEE 21st International Conference on Micro Electro Mechanical Systems. Presented at the 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems.
Event: 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems
2008 journal article
Fabrication of Flexible Transducer Arrays With Through-Wafer Electrical Interconnects Based on Trench Refilling With PDMS
Journal of Microelectromechanical Systems, 17(2), 446–452.
2008 journal article
Forward-looking intracardiac ultrasound imaging using a 1-D CMUT array integrated with custom front-end electronics
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 55(12), 2651–2660.
2008 journal article
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 55(2), 327–342.
2008 conference paper
Investigating large 2D arrays for photoacoustic and acoustic imaging using CMUT technology
2008 IEEE Ultrasonics Symposium. Presented at the 2008 IEEE Ultrasonics Symposium (IUS).
Event: 2008 IEEE Ultrasonics Symposium (IUS)
2008 speech
Miniaturized chemical sensor array for detection of warfare agents
Park, K. K., Lee, H. J., Kupnik, M., Oralkan, Ö., & Khuri-Yakub, B. T. (2008, May). Presented at the 8th International Symposium on Technology and the Mine Problem Naval Postgraduate School, Monterey, CA.
Event: 8th International Symposium on Technology and the Mine Problem Naval Postgraduate School at Monterey, CA on May 6-8, 2008
2008 journal article
Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 55(7), 1570–1581.
2008 conference paper
Optimum design of circular CMUT membranes for high quality factor in air
2008 IEEE Ultrasonics Symposium. Presented at the 2008 IEEE Ultrasonics Symposium (IUS).
Event: 2008 IEEE Ultrasonics Symposium (IUS)
2008 conference paper
The effect of parallelism of CMUT cells on phase noise for chem/bio sensor applications
2008 IEEE Ultrasonics Symposium. Presented at the 2008 IEEE Ultrasonics Symposium (IUS).
Event: 2008 IEEE Ultrasonics Symposium (IUS)
2008 chapter
Ultrasonic Transduction
In Comprehensive Microsystems (pp. 517–539).
2007 conference paper
10C-6 Fully Integrated CMUT-Based Forward-Looking Intracardiac Imaging for Electrophysiology
2007 IEEE Ultrasonics Symposium Proceedings. Presented at the 2007 IEEE Ultrasonics Symposium.
Event: 2007 IEEE Ultrasonics Symposium
2007 conference paper
2C-3 An Integrated Circuit with Transmit Beamforming and Parallel Receive Channels for 3D Ultrasound Imaging: Testing and Characterization
2007 IEEE Ultrasonics Symposium Proceedings. Presented at the 2007 IEEE Ultrasonics Symposium Proceedings.
Event: 2007 IEEE Ultrasonics Symposium Proceedings
2007 conference paper
A co-axial scanning acoustic and photoacoustic microscope
Proceedings of the IEEE Ultrasonics Symposium, 2413–2416.
2007 journal article
Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen
Applied Physics Letters, 91(9), 094102.
2007 conference paper
Design of HIFU CMUT Arrays for Treatment of Liver and Renal Cancer
AIP Conference Proceedings. Presented at the 6TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND.
Event: 6TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND
2007 journal article
Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 54(2), 418–430.
2007 conference paper
Flexible transducer arrays with through-wafer electrical interconnects based on trench refilling with PDMS
2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS). Presented at the 2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS).
Event: 2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS)
2007 journal article
Integration of trench-isolated through-wafer interconnects with 2d capacitive micromachined ultrasonic transducer arrays
Sensors and Actuators A: Physical, 138(1), 221–229.
2007 chapter
Micromachined ultrasonic transducers
In McGraw-Hill Yearbook of Science and Technology 2008 (pp. 207–210). New York: McGraw-Hill Professional.
2007 conference paper
The capacitive micromachined ultrasonic transducer (CMUT) as a chem/bio sensor
Proceedings of the IEEE Ultrasonics Symposium, 472–475.
2007 conference paper
Trench-isolated CMUT arrays with a supporting frame: characterization and imaging results
Proceedings of the IEEE Ultrasonics Symposium, 507–510.
2006 conference paper
1E-3 Tomographic Photoacoustic Imaging Using Capacitive Micromachined Ultrasonic Transducer (CMUT) Technology
2006 IEEE Ultrasonics Symposium. Presented at the 2006 IEEE Ultrasonics Symposium.
Event: 2006 IEEE Ultrasonics Symposium
2006 conference paper
1I-2 Capacitive Micromachined Ultrasonic Transducers for High Intensity Focused Ablation of Upper Abdominal Tumors
2006 IEEE Ultrasonics Symposium. Presented at the 2006 IEEE Ultrasonics Symposium.
Event: 2006 IEEE Ultrasonics Symposium
2006 journal article
3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 53(6), 1202–1211.
2006 conference paper
3-D ultrasound imaging using forward viewing CMUT ring arrays for intravascular and intracardiac applications
IEEE Ultrasonics Symposium, 2005. Presented at the IEEE Ultrasonics Symposium, 2005.
Event: IEEE Ultrasonics Symposium, 2005.
2006 conference paper
5G-6 Forward Looking Intracardiac Imaging Catheters for Electrophysiology
Proceedings of the 2006 IEEE Ultrasonics Symposium, 702–705.
Event: 2006 IEEE Ultrasonics Symposium
2006 conference paper
5I-6 Finite Element Analysis of Fabrication Related Thermal Effects in Capacitive Micromachined Ultrasonic Transducers
2006 IEEE Ultrasonics Symposium. Presented at the 2006 IEEE Ultrasonics Symposium.
Event: 2006 IEEE Ultrasonics Symposium
2006 conference paper
An endoscopic imaging system based on a two-dimensional CMUT array: real-time imaging results
IEEE Ultrasonics Symposium, 2005. Presented at the IEEE Ultrasonics Symposium, 2005.
Event: IEEE Ultrasonics Symposium, 2005.
2006 conference paper
Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3D catheter-based ultrasonic imaging
In S. Emelianov & W. F. Walker (Eds.), Medical Imaging 2006: Ultrasonic Imaging and Signal Processing.
Ed(s): S. Emelianov & W. Walker
Event: Medical Imaging
2006 conference paper
Capacitive micromachined ultrasonic transducer arrays for integrated diagnostic/therapeutic catheters
AIP Conference Proceedings, 829(1), 395–399.
Event: Therapeutic Ultrasound: 5th International Symposium on Therapeutic Ultrasound
2006 conference paper
Capacitive micromachined ultrasonic transducers (CMUTs) for photoacoustic imaging
In A. A. Oraevsky & L. V. Wang (Eds.), Photons Plus Ultrasound: Imaging and Sensing 2006: The Seventh Conference on Biomedical Thermoacoustics, Optoacoustics, and Acousto-optics.
Ed(s): A. Oraevsky & L. Wang
Event: Biomedical Optics 2006
2006 conference paper
Characterization of cross-coupling in capacitive micromachined ultrasonic transducers
IEEE Ultrasonics Symposium, 2005. Presented at the IEEE Ultrasonics Symposium, 2005.
Event: IEEE Ultrasonics Symposium, 2005.
2006 journal article
Experimental characterization of collapse-mode CMUT operation
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 53(8), 1513–1523.
2006 conference paper
High-resolution imaging with high-frequency 1-D linear CMUT arrays
IEEE Ultrasonics Symposium, 2005. Presented at the IEEE Ultrasonics Symposium, 2005.
Event: IEEE Ultrasonics Symposium, 2005.
2006 journal article
IVUS beyond the horizon
EuroIntervention, 2(1), 132–142.
2006 conference paper
Interconnection and Packaging for 2D Capacitive Micromachined Ultrasonic Transducer Arrays Based on Through-Wafer Trench Isolation
19th IEEE International Conference on Micro Electro Mechanical Systems. Presented at the 19th IEEE International Conference on Micro Electro Mechanical Systems.
Event: 19th IEEE International Conference on Micro Electro Mechanical Systems
2006 conference paper
P2P-6 Trench-Isolated CMUT Arrays with a Supporting Frame
2006 IEEE Ultrasonics Symposium. Presented at the 2006 IEEE Ultrasonics Symposium.
Event: 2006 IEEE Ultrasonics Symposium
2006 conference paper
P3H-6 An Integrated Circuit with Transmit Beamforming and Parallel Receive Channels for Real-Time Three-Dimensional Ultrasound Imaging
2006 IEEE Ultrasonics Symposium. Presented at the 2006 IEEE Ultrasonics Symposium.
Event: 2006 IEEE Ultrasonics Symposium
2006 conference paper
P3H-7 Volumetric Imaging Using Fan-Beam Scanning with Reduced Redundancy 2D Arrays
2006 IEEE Ultrasonics Symposium. Presented at the 2006 IEEE Ultrasonics Symposium.
Event: 2006 IEEE Ultrasonics Symposium
2006 conference paper
Photoacoustic imaging using a two-dimensional CMUT array
IEEE Ultrasonics Symposium, 2005. Presented at the IEEE Ultrasonics Symposium, 2005.
Event: IEEE Ultrasonics Symposium, 2005.
2006 conference paper
Through-wafer trench-isolated electrical interconnects for CMUT arrays
IEEE Ultrasonics Symposium, 2005. Presented at the IEEE Ultrasonics Symposium, 2005.
Event: IEEE Ultrasonics Symposium, 2005.
2005 conference paper
A miniature real-time volumetric ultrasound imaging system
In W. F. Walker & S. Y. Emelianov (Eds.), Medical Imaging 2005: Ultrasonic Imaging and Signal Processing.
Ed(s): W. Walker & S. Emelianov
Event: Medical Imaging
2005 conference paper
CMUT ring arrays for forward-looking intravascular imaging
IEEE Ultrasonics Symposium, 2004. Presented at the IEEE Ultrasonics Symposium, 2004.
Event: IEEE Ultrasonics Symposium, 2004
2005 journal article
Capacitive micromachined ultrasonic transducer design for high power transmission
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 52(2), 326–339.
2005 conference paper
Capacitive micromachined ultrasonic transducer technology for medical ultrasound imaging
In W. F. Walker & S. Y. Emelianov (Eds.), Medical Imaging 2005: Ultrasonic Imaging and Signal Processing.
Ed(s): W. Walker & S. Emelianov
Event: Medical Imaging
2005 journal article
Capacitive micromachined ultrasonic transducers: fabrication technology
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 52(12), 2242–2258.
2005 journal article
Coherent array imaging using phased subarrays. Part II: simulations and experimental results
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 52(1), 51–64.
2005 conference paper
Dynamic FEM analysis of multiple cmut cells in immersion
IEEE Ultrasonics Symposium, 2004. Presented at the IEEE Ultrasonics Symposium, 2004.
Event: IEEE Ultrasonics Symposium, 2004
2005 journal article
Dynamic analysis of capacitive micromachined ultrasonic transducers
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 52(12), 2270–2275.
2005 conference paper
High-frequency CMUT arrays for high-resolution medical imaging
In W. F. Walker & S. Y. Emelianov (Eds.), Medical Imaging 2005: Ultrasonic Imaging and Signal Processing.
Ed(s): W. Walker & S. Emelianov
Event: Medical Imaging
2005 conference paper
High-frequency CMUT arrays for high-resolution medical imaging
IEEE Ultrasonics Symposium, 2004. Presented at the IEEE Ultrasonics Symposium, 2004.
Event: IEEE Ultrasonics Symposium, 2004
2005 conference paper
Integrated ultrasonic imaging systems based on CMUT arrays: recent progress
IEEE Ultrasonics Symposium, 2004. Presented at the IEEE Ultrasonics Symposium, 2004.
Event: IEEE Ultrasonics Symposium, 2004
2005 conference paper
Integrated ultrasound imaging systems based on capacitive micromachined ultrasonic transducer arrays
Proceedings of the IEEE Conference on Sensors, 704–707.
2005 chapter
Techniques and Applications of Capacitive Micromachined Ultrasonic Transducers
In C. T. Leondes (Ed.), Fabrication Techniques for MEMS/NEMS (pp. 223–280). New York: Springer.
Ed(s): C. Leondes
2005 conference paper
Two-dimensional capacitive micromachined ultrasonic transducer (CMUT) arrays for a miniature integrated volumetric ultrasonic imaging system
In W. F. Walker & S. Y. Emelianov (Eds.), Medical Imaging 2005: Ultrasonic Imaging and Signal Processing.
Ed(s): W. Walker & S. Emelianov
Event: Medical Imaging
2005 conference paper
Underwater acoustic imaging using capacitive micromachined ultrasonic transducer arrays
Oceans '02 MTS/IEEE. Presented at the Oceans 2002 Conference and Exhibition.
Event: Oceans 2002 Conference and Exhibition.
2004 journal article
Forward-viewing CMUT arrays for medical imaging
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 51(7), 887–895.
2004 chapter
Micromachined Ultrasonic Transducers and Their use for 2D and 3D Imaging
In Acoustical Imaging (pp. 1–9).
2004 conference paper
Phased subarray imaging for low-cost, wideband coherent array imaging
IEEE Symposium on Ultrasonics, 2003. Presented at the IEEE Symposium on Ultrasonics, 2003.
Event: IEEE Symposium on Ultrasonics, 2003
2003 journal article
A multichannel pipeline analog-to-digital converter for an integrated 3-d ultrasound imaging system
IEEE Journal of Solid-State Circuits, 38(7), 1266–1270.
2003 conference paper
Broadband capacitive micromachined ultrasonic transducers ranging from 10 kHz to 60 MHz for imaging arrays and more
2002 IEEE Ultrasonics Symposium, 2002. Proceedings. Presented at the 2002 IEEE International Ultrasonics Symposium.
Event: 2002 IEEE International Ultrasonics Symposium
2003 conference paper
Simulation and experimental characterization of a 2-D, 3-MHz capacitive micromachined ultrasonic transducer (CMUT) array element
1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027). Presented at the 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium.
Event: 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium
2003 conference paper
Volumetric imaging using 2D capacitive micromachined ultrasonic transducer arrays (CMUTs): initial results
2002 IEEE Ultrasonics Symposium, 2002. Proceedings. Presented at the 2002 IEEE International Ultrasonics Symposium.
Event: 2002 IEEE International Ultrasonics Symposium
2003 journal article
Volumetric ultrasound imaging using 2-D CMUT arrays
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 50(11), 1581–1594.
2002 conference paper
A multichannel, pipeline analog-to- digital converter for an integrated 3-D ultrasound imaging system
Proceedings of the European SolidState Circuits Conference (ESSCIRC), 263–266.
2002 conference paper
Capacitive micromachined ultrasonic transducer arrays for medical imaging: experimental results
2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263). Presented at the 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.
Event: 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium
2002 journal article
Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 49(11), 1596–1610.
2002 conference paper
Design of all-pole low-pass ladder filters using current-mode damped integrators
1996 IEEE International Symposium on Circuits and Systems. Circuits and Systems Connecting the World. ISCAS 96. Presented at the 1996 IEEE International Symposium on Circuits and Systems. Circuits and Systems Connecting the World. ISCAS 96.
Event: 1996 IEEE International Symposium on Circuits and Systems. Circuits and Systems Connecting the World. ISCAS 96
2002 conference paper
Differentiation between electric breakdowns and dielectric breakdown in thin silicon oxides
Proceedings of the 1997 6th International Symposium on the Physical and Failure Analysis of Integrated Circuits. Presented at the 1997 6th International Symposium on the Physical and Failure Analysis of Integrated Circuits.
Event: 1997 6th International Symposium on the Physical and Failure Analysis of Integrated Circuits
2002 journal article
Medical imaging using capacitive micromachined ultrasonic transducer arrays
Ultrasonics, 40(1-8), 471–476.
2002 conference paper
The non-uniqueness of breakdown distributions in silicon oxides
1997 IEEE International Integrated Reliability Workshop Final Report (Cat. No.97TH8319). Presented at the 1997 IEEE International Integrated Reliability Workshop Final Report.
Event: 1997 IEEE International Integrated Reliability Workshop Final Report
2001 journal article
An ultrasonic volumetric scanner for image-guided surgery
International Congress Series, 1230, 190–196.
2001 journal article
Characterization of one-dimensional capacitive micromachined ultrasonic immersion transducer arrays
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 48(3), 750–760.
2001 conference paper
Micromachined capacitor ultrasonic transducers
Program and Extended Abstracts of The 10th US-Japan Seminar on Dielectric and Piezoelectric Ceramics, 391–399.
Event: 10th US-Japan Seminar on Dielectric and Piezoelectric Ceramics at Providence, Rhode Island on September 26-29, 2001
2000 conference paper
Initial pulse-echo imaging results with onedimensional capacitive micromachined ultrasonic transducer arrays
Proceedings of the IEEE Ultrasonics Symposium, 1, 959–962.
2000 journal article
Silicon Micromachined Ultrasonic Transducers
Japanese Journal of Applied Physics, 39(Part 1, No. 5B), 2883–2887.
Ed(s): M. Zakharia, P. Chevret & P. Dubail
2000 conference paper
Silicon micromachined ultrasonic transducers
In M. E. Zakharia, P. Chevret, & P. Dubail (Eds.), Proceedings of the ASME Noise Control and Acoustic Division (pp. 153–171). New York: The American Society of Mechanical Engineers.
Ed(s): M. Zakharia, P. Chevret & P. Dubail
1999 journal article
Electric breakdowns and breakdown mechanisms in ultra-thin silicon oxides
Microelectronics Reliability, 39(2), 171–179.
1999 conference paper
Recent progress in capacitive micromachined ultrasonic immersion transducer array
Proceedings of the 8th International Symposium on Integrated Circuits, Devices and Systems, 159–162.
1999 journal article
Simulation and experimental characterization of a 2-D capacitive micromachined ultrasonic transducer array element
IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 46(6), 1337–1340.
1998 journal article
Differentiation Between Electric Breakdowns and Dielectric Breakdown in Thin Silicon Oxides
Journal of The Electrochemical Society, 145(3), 1033.
1998 journal article
The Search for Cathode and Anode Traps in High-Voltage Stressed Silicon Oxides
Journal of The Electrochemical Society, 145(4), 1292.
1997 conference paper
Differentiation between electric breakdowns and dielectric breakdown in thin silicon oxides
Proceeding of the Symposium on Silicon Nitride and Silicon Dioxide Thin Insulating Films, 20–33.
1997 journal article
Nonuniqueness of time-dependent-dielectric-breakdown distributions
Applied Physics Letters, 71(25), 3682–3684.
1997 conference paper
The search for cathode and anode traps in high-voltage stressed silicon oxides
Proceedings of the Symposium on Silicon Nitride and Silicon Dioxide Thin Insulating Films, 88–98.
Updated: June 13th, 2020 13:22
Updated: August 10th, 2018 09:36
1998 - 2003
Citation Index includes data from a number of different sources. If you have questions about the sources of data in the Citation Index or need a set of data which is free to re-distribute, please contact us.
Certain data included herein are derived from the Web of Science© and InCites© (2024) of Clarivate Analytics. All rights reserved. You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.