@article{oda_wang_hampton_robertson_posner_2022, title={Perianesthetic mortality in English Bulldogs: a retrospective analysis in 2010-2017}, volume={18}, ISSN={["1746-6148"]}, DOI={10.1186/s12917-022-03301-9}, abstractNote={Abstract Background Many veterinarians consider English Bulldogs to have a greater perianesthetic mortality risk. The aims of this study were to 1) determine total and anesthesia-related, perianesthetic mortality (PAM) rates in English Bulldogs (EB), 2) identify potential risk factors associated with mortality in EB, and 3) determine the difference in the perianesthetic mortality rates between EB, other-brachycephalic breeds (OB), and non-brachycephalic breeds (NB). Records from EB that were anesthetized between 2010 and 2017, were investigated. OB and NB were enrolled to match with each EB based on a procedure and age from the study period. Data collected in EB included: age, ASA status, weight, procedure types, anesthetic and analgesic management, anesthetic duration, anesthetic recovery location, and cause of death. Age and cause of death were determined from OB and NB. Fisher’s exact test was used to compare PAM rate and age in EB, OB, and NB. Mann–Whitney U test was used to compare EB survivor and EB non-survivor. Logistic regression models were used to identify factors and odds ratio (OR) associated with PAM in EB. Result Two hundred twenty nine EB, 218 OB, and 229 NB were identified. The total and anesthesia-related PAM rates in EB were 6.6 and 3.9%, respectively. EB had a greater total PAM rate compared with OB (p = 0.007). ASA status was different between survivors and non-survivors in EB (p < 0.01). Risk factors identified regardless of the cause of death were premedication with full μ opioids (OR = 0.333, p = 0.114), continuous infusion of ketamine post-operatively (OR = 13.775, p = 0.013), and acepromazine administration post-operatively (OR = 7.274, p = 0.004). The most common cause of death in EB was postoperative respiratory dysfunction (87.5%). Conclusion Total and anesthesia-related mortality in EB is considerable. Most deaths in EB occurred during the postoperative period secondary to respiratory complications. }, number={1}, journal={BMC VETERINARY RESEARCH}, author={Oda, Ayako and Wang, Wen Hui and Hampton, Amanda K. and Robertson, James B. and Posner, Lysa P.}, year={2022}, month={May} } @article{wang_lynch_balko_duffy_robertson_posner_2022, title={Point-of-care viscoelastic coagulation assessment in healthy dogs during the perianesthetic period}, volume={18}, ISSN={["1746-6148"]}, DOI={10.1186/s12917-022-03442-x}, abstractNote={Abstract Background The viscoelastic coagulation monitor (VCM Vet) is a novel, portable device that provides a global assessment of hemostasis. The study aims were to evaluate serial viscoelastic analysis during the perianesthetic period in healthy dogs and to compare the agreement between two VCM Vet devices. Twenty healthy dogs undergoing orthopedic surgery were enrolled. Whole blood samples were collected from an intravenous catheter at four time points: baseline, 15 min after premedication, 60 min after inhalant initiation, and 60 min after inhalant termination. Viscoelastic tests were performed in duplicate on different devices, providing: clot time (CT; seconds), clot formation time (CFT; seconds), alpha angle (α; degrees), amplitude (units) at 10 (A10) and 20 (A20) minutes post clot time, maximum clot firmness (MCF; units), and lysis index (%) at 30 (Li30) and 45 (Li45) minutes post maximum clot formation. Results One hundred sixty samples were analyzed. The speed of CT and CFT significantly decreased an average of 25.5 s (95% confidence interval [CI]15.9–35.0) and 6.9 s (95% CI 3.1–10.7) per time point, respectively. There were no significant changes in clot strength or lysis variables. The Bland–Altman style plot shows an acceptable rate of agreement for all variables with intra-class correlation ranging from 0.64–0.94. Conclusion The rate of clot formation (CT and CFT) decreased over the perianesthetic period in healthy dogs undergoing surgery. These changes were small and occurred without changes in clot strength or fibrinolysis rate, thus were not clinically relevant. There was clinically acceptable consistency between devices. }, number={1}, journal={BMC VETERINARY RESEARCH}, author={Wang, Wen H. and Lynch, Alex M. and Balko, Julie A. and Duffy, Daniel J. and Robertson, James B. and Posner, Lysa P.}, year={2022}, month={Sep} }