Mechanical and Aerospace Engineering

Works Published in 2015

search works

Displaying works 101 - 120 of 296 in total

Sorted by most recent date added to the index first, which may not be the same as publication date order.

2015 conference paper

A low-power wearable substance monitoring device

2015 Virtual Conference on Application of Commercial Sensors.

TL;DR: Developing a device in the form of a wrist-watch that is capable of measuring selected physiological parameters using commercially available sensors and an Android application with algorithms capable of determining if the user is under the influence of alcohol or drugs has been developed and tested. (via Semantic Scholar)
UN Sustainable Development Goal Categories
3. Good Health and Well-being (OpenAlex)
Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

Top down design using Bayesian network classifiers for composite panels

Proceedings of the American Society for Composites: Thirtieth Technical Conference, 468–475.

By: K. Von Hagel, S. Joglekar, S. Ferguson & M. Pankow

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

Student simulation challenge: A competition-based composites education opportunity

Proceedings of the American Society for Composites: Thirtieth Technical Conference, 1160–1170.

By: K. Pochiraju, E. Iarve, B. Haque & M. Pankow

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

Nox reduction in partially premixed flames by flue gas recirculation

Proceedings of the ASME International Mechanical Engineering Congress and Exposition, 2014, vol 8b.

By: Y. Chudnovsky*, S. Zelepouga*, A. Saveliev n, J. Wagner* & V. Gnatenko*

UN Sustainable Development Goal Categories
7. Affordable and Clean Energy (OpenAlex)
Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

Modeling of 3D woven composites with realistic geometry for accurate prediction of kinking under compressive loads

Proceedings of the American Society for Composites: Thirtieth Technical Conference, 593–612.

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

High-speed 3D digital image correlation of low-velocity impacts on composite plates

Proceedings of the American Society for Composites: Thirtieth Technical Conference, 2120–2135.

By: M. Flores, D. Mollenhauer, V. Runatunga, T. Berbeniss, D. Rapking & M. Pankow

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

Enhancement of ultrasonic cavitation yield by dual frequency sonication

Proceedings of the ASME International Mechanical Engineering Congress and Exposition, 2014, vol 3.

By: S. Guo n & X. Jiang n

Source: NC State University Libraries
Added: August 6, 2018

2015 journal article

Critical lithiation for C-rate dependent mechanical stresses in LiFePO4

Journal of Solid State Electrochemistry, 19(8), 2245–2253.

By: C. ChiuHuang n & H. Huang n

author keywords: Diffusion-induced stresses; Lithium-ion batteries; Concentration gradient; Crack; Finite element method
UN Sustainable Development Goal Categories
2. Zero Hunger (OpenAlex)
Sources: Web Of Science, Crossref, ORCID
Added: August 6, 2018

2015 conference paper

Characterization of delamination in translaminar reinforced composites due to low velocity impact

Proceedings of the American Society for Composites: Thirtieth Technical Conference, 381–392.

By: V. Ranatunga, S. Joglekar, M. Pankow & S. Clay

Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

Anti-matching design for wave isolation in dual frequency transducer for intravascular super-harmonic imaging

Proceedings of the ASME International Mechanical Engineering Congress and Exposition, 2014, vol 3.

By: J. Ma n, S. Li n, Z. Wang n & X. Jiang n

TL;DR: High resolution image was generated from super-harmonic imaging, which elucidated the capability of the transducer for intravascular microvessel detection and suppressed the aliasing echo to less than −20 dB. (via Semantic Scholar)
Source: NC State University Libraries
Added: August 6, 2018

2015 conference paper

A bi-frequency co-linear array transducer for biomedical ultrasound imaging

Proceedings of the ASME International Mechanical Engineering Congress and Exposition, 2014, vol 3.

TL;DR: A bi-frequency co-linear array covering a frequency range of 5 MHz-20 MHz was investigated to meet the requirements of resolution and depth of field for a broad range of ultrasound imaging applications. (via Semantic Scholar)
Source: NC State University Libraries
Added: August 6, 2018

2015 article

Dual-frequency intravascular ultrasound imaging of microbubble contrast agents: Ex vivo and in vivo demonstration

2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS).

By: B. Lindsey*, K. Martin*, P. Dayton*, J. Ma n, Z. Wang n & X. Jiang n

author keywords: microbubble; intravascular ultrasound; vasa vasorum; high frequency ultrasound
TL;DR: The results of this study suggest contrast-specific intravascular ultrasound imaging for the detection of vulnerable plaques in atherosclerosis may provide additional diagnostic information. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Source: Web Of Science
Added: August 6, 2018

2015 article

Dual-frequency IVUS transducer for acoustic radiation force impulse (ARFI) imaging

2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS).

author keywords: dual frequency ultrasound; ultrasound transducer; intravascular ultrasound; IVUS; acoustic radiation force; ARFI
TL;DR: A dual-frequency IVUS transducer, consisting of a 6.5 MHz “pushing” element and a 26 MHz ‘tracking’ element, was designed and fabricated for ARFI application and suggests great potential of this dual- frequencies for intravascular ARFI imaging. (via Semantic Scholar)
UN Sustainable Development Goal Categories
3. Good Health and Well-being (Web of Science; OpenAlex)
Source: Web Of Science
Added: August 6, 2018

2015 article

Dual-frequency IVUS array for contrast enhanced intravascular ultrasound imaging

2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS).

By: Z. Wang n, W. Huang n, X. Jiang n, K. Martin n & P. Dayton n

author keywords: dual frequency ultrasound; transducer array; lateral mode transducer; superharmonic; CE-IVUS; microbubble
TL;DR: A prototyped dual-frequency array for CE-IVUS imaging was developed and tested and images of a contrast-filled microtube can be observed clearly with only 4 receiving elements at an excitation voltage of 55 V, which indicates feasibility of CE- IVUS imaging after circularly wrapping the array for catheter integration. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Source: Web Of Science
Added: August 6, 2018

2015 journal article

Broadband Acoustic Hyperbolic Metamaterial

PHYSICAL REVIEW LETTERS, 115(25).

By: C. Shen n, Y. Xie*, N. Sui n, W. Wang*, S. Cummer* & Y. Jing n

TL;DR: The proposed metamaterial consists of multiple arrays of clamped thin plates facing the y direction and is shown to yield opposite signs of effective density in the x and y directions below a certain cutoff frequency, yielding a hyperbolic dispersion. (via Semantic Scholar)
Source: Web Of Science
Added: August 6, 2018

2015 article

A PMN- PT Micromachined 1-3 Composite Circular Array for IVUS

2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS).

By: S. Li n, X. Jiang n, J. Tian, P. Han & C. Zhang*

author keywords: micromachined 1-3 composite; high frequency; intravascular imaging; ultrasound array
TL;DR: The results demonstrated beam widths exceeding 70 μm axially imply the great potential of the developed array transducer for the high frequency medical imaging. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Source: Web Of Science
Added: August 6, 2018

2015 article

A 3 MHz/18 MHz Dual-layer Co-Linear Array for Transrectal Acoustic Angiography

2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS).

By: S. Li n, J. Kim n, Z. Wang n, X. Jiang n, S. Kasoji n, B. Lindsey n, P. Dayton n

author keywords: acoustic angiography; dual frequency; ultrasound contrast agent; transrectal ultrasound; prostate cancer
TL;DR: Results suggest that the prototyped co-linear array is capable of performing dual-frequency superharmonic imaging of microbubbles (“acoustic angiography”) for prostate cancer assessment. (via Semantic Scholar)
UN Sustainable Development Goal Categories
Source: Web Of Science
Added: August 6, 2018

2015 article

Spatiotemporal drug delivery using laser-generated-focused ultrasound system

Di, J., Kim, J., Hu, Q., Jiang, X., & Gu, Z. (2015, December 28). JOURNAL OF CONTROLLED RELEASE, Vol. 220, pp. 592–599.

By: J. Di n, J. Kim n, Q. Hu n, X. Jiang n & Z. Gu n

author keywords: Drug delivery; Photoacoustic; Nanoparticles; Microgels; Stimuli responsive
MeSH headings : Alginates / chemistry; Anti-Bacterial Agents / administration & dosage; Anti-Bacterial Agents / chemistry; Antibiotics, Antineoplastic / administration & dosage; Antibiotics, Antineoplastic / chemistry; Cell Proliferation / drug effects; Cell Survival / drug effects; Chemistry, Pharmaceutical; Ciprofloxacin / administration & dosage; Ciprofloxacin / chemistry; Delayed-Action Preparations; Dimethylpolysiloxanes / chemistry; Disk Diffusion Antimicrobial Tests; Doxorubicin / administration & dosage; Doxorubicin / chemistry; Drug Carriers; Equipment Design; Escherichia coli / drug effects; Escherichia coli / growth & development; Gels; Glucuronic Acid / chemistry; HeLa Cells; Hexuronic Acids / chemistry; Humans; Kinetics; Lactic Acid / chemistry; Lasers; Nanoparticles; Photoacoustic Techniques; Polyglycolic Acid / chemistry; Polylactic Acid-Polyglycolic Acid Copolymer; Solubility; Soot / chemistry; Spheroids, Cellular; Technology, Pharmaceutical / instrumentation; Technology, Pharmaceutical / methods; Transducers; Ultrasonic Waves; Ultrasonics / instrumentation; Ultrasonics / methods
TL;DR: This novel LGFU-responsive drug delivery system provides a simple and remote approach to precisely control the release of therapeutics in a spatiotemporal manner and potentially suppress detrimental effects to the surrounding tissue, such as thermal ablation. (via Semantic Scholar)
Source: Web Of Science
Added: August 6, 2018

2015 conference paper

Rapid processing of full-spectral data from embedded FBG sensors

Structural health monitoring 2015: system reliability for verification and implementation, vols. 1 and 2, 1729–1736.

By: K. Peters* & S. Webb*

Sources: NC State University Libraries, NC State University Libraries
Added: August 6, 2018

2015 conference paper

Pulse phase thermography inspection of bond defects in environmentally conditioned FRP-to-concrete specimens

Structural health monitoring 2015: system reliability for verification and implementation, vols. 1 and 2, 424–431.

By: N. Mabry, R. Seracino* & K. Peters*

Sources: NC State University Libraries, NC State University Libraries
Added: August 6, 2018

Citation Index includes data from a number of different sources. If you have questions about the sources of data in the Citation Index or need a set of data which is free to re-distribute, please contact us.

Certain data included herein are derived from the Web of Science© and InCites© (2024) of Clarivate Analytics. All rights reserved. You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.